Skip to main content

Best Practices in integrating web page recording

Overview

External factors can cause problems with web page recording, including the following:

  • The page to be recorded cannot be accessed normally because the page fails to load or takes too long. In response to this problem, Agora provides a web page load timeout detection function.
  • The page to be recorded can be accessed normally, but the HTML elements in the page cannot be loaded correctly.
  • The page fails to load during the recording process because changed HTML elements do not load normally.
  • The audio or video in the page to be recorded cannot be played normally.
  • Web page recording stops abnormally.

To ensure reliability and consistency in the face of network issues, Agora recommends the following best practices.

Ensure the recording service starts successfully

Take the following steps to ensure that the recording service starts successfully:

  1. Ensure that the start request is successful, that is, you receive a sid (recording ID) from the response. If the request fails, take measures according to the HTTP status code:
    • If the returned HTTP status code is always 40x, check the parameter values in your request.
    • If the returned HTTP status code is 50x, you can retry several times with the same parameters until you receive a sid. Agora recommends that you use a backoff strategy, for example, retry after 3, 6, and 9 seconds successively, to avoid exceeding the QPS limits. If you retry three times and still do not get a sid, retry with a new user ID.
    • If you receive error code 65, retry with the same parameters. Agora recommends that you use a backoff strategy, for example, retry after 3 and 6 seconds successively.
  2. Five seconds after you receive a sid, use a backoff strategy to call query, for example, retry after 5, 10 and 15 seconds successively. If the query call succeeds, and status in serverResponse is 4 or 5, it means the recording service starts successfully. Otherwise, you can deem the recording service as not having started, or quit halfway after starting.

Ensure the page to be recorded loads successfully

1. Regularly reports whether the page to be recorded loads successfully

Before starting web page recording, you need to complete the page detection logic of the JavaScript of the web page to be recorded to implement the following solutions:

  1. When calling start to start web page recording, the web page recording browser accesses and loads the web page to be recorded.
  2. The web page recording service executes the page detection logic of the JavaScript of the web page to be recorded. When a web page element is loaded in line with your expectations, the recording ID (sid) associated with the web page recording service callback informs the business server that the recording service has started successfully.
  3. The web page server reports its status at regular intervals to notify the business server of any content changes.

2. Reinitiate recording requests when the web page fails to load

Agora recommends that you use the detection logic of the page to be recorded to determine if the recording fails to start, that is, if the business server fails to receive a callback that indicates that the loading of the web page is as expected. In such a case, you should reinitiate the recording request.

Use the web_recorder_stopped callback to detect abnormal recording stoppages

Open the message notification service, and subscribe to the 71 web_recorder_stopped callback event. When the business server receives the web_recorder_stopped callback and the code is not 0, it means that the web page recording has stopped abnormally. Agora recommends that you restart the recording process and create a new recording.

Page Content